IFP-2000
Scalable Analog/Addressable Fire Alarm Control
• 636 points per panel
• Networkable with up to 8 nodes (16 nodes for Select Distributors) for a total of 5088 points
• 2 SBUSs
• 8 Flexput® circuits that can be programmed as auxiliary power, notification appliance output, or as a conventional input.
• 9 amps of power
• Class A or B wiring for NACs, SBUS, and network.
• Compatible with either IDP (System Sensor) devices or SD (Hochiki) devices.
• Network dialing gives allows you to dial from one control panel on a network saving you money on telephone lines
• 4 x 40 LCD display
• Built-in synchronization for System Sensor®, AMSECO, Gentex®, or Wheelock®
|
|
 |
IFP-1000
Analog/Addressable Fire Alarm Control
• One onboard SLC circuit that can support 99 IDP (System Sensor) devices/99 IDP modules, or 127 SD (Hochiki) devices. Expandable to a total of 792 devices/792 modules IDP, or 1016 SD devices.
• 6 amps of power
• 6 Flexput circuits that can be programmed as auxiliary power, notification appliance output, or as a conventional input
• Built-in UL listed DACT (digital alarm communicator transmitter)
• 1 SBUS
• 4 X 20 LCD display
• Built-in synchronization for System Sensor®, AMSECO, Gentex®, or Wheelock®
|
 |
IFP-100
Analog/Addressable Fire Alarm Control
• One onboard SLC circuit that can support 99 IDP (System Sensor) devices/99 IDP modules, or 127 SD (Hochiki) devices
• 6 amps of power
• 4 Notification circuits that can be programmed as either aux power or as a notification output
• Built-in UL listed DACT (digital alarm communicator transmitter)
• 1 SBUS
• 4 X 20 LCD display
• Built-in synchronization for System Sensor®, AMSECO, Gentex®, or Wheelock® |
|
 |
IFP-50
Analog/Addressable Fire Alarm Control
• One onboard SLC circuit that can support 50 IDP (System Sensor) devices/50 IDP modules, or 50 SD (Hochiki) devices
• 2.5 amps of power
• 2 Notification circuits that can be programmed as either aux power or as a notification output
• Built-in UL listed DACT (digital alarm communicator transmitter)
• 1 SBUS
• 4 X 20 LCD display
• Built-in synchronization for System Sensor®, AMSECO, Gentex®, or Wheelock®
|
 |
IFP-25
Hybrid Conventional-Addressable Fire Alarm Control
• Combines the convenience of conventional control panel programming and configuration using addressable devices that provide all the data required for calibrated smoke test as required by NFPA 72
• Built-in support for a combination of up to 25 Honeywell Fire System detectors and modules
• Programming is easily done just by setting the code wheels on the detectors or devices then the control panel automatically maps them to the correct zone.
• Custom programming can be done with a laptop by simple plugging into the control panel and opening your web browser, the control panel has a built-in web page dedicated to system programming.
• Built-in synchronization for System Sensor®, AMSECO, Gentex®, or Wheelock®
|
|
|
|
|
|
|
 |
IFP-2000ECS
• Scalable Analog/Addressable Fire Alarm Control w/Integrated Emergency Communication System
• All the features of the IFP-2000 fire alarm control panel
• Can Select ECS message as priority over fire alarm
• 15 recordable messages that can be mapped to eight ECS buttons
• Supports up to 7 ECS-RCU2000’s. The ECS-RCU2000 meets the requirements for a LOC
• Programmable trigger inputs from an external source , such as a Monaco system, to either the VCM, RVM, or 5880. Up to 8 inputs available on each 5880 module
• Fire alarm and ECS combined in one easy to program system
• Supports up to 128 speaker circuits that can be easily mapped with programming software.
• Uses distributed amplifier that can provide up to 2000 watts of power using either the ECS-DUAL50W (50/100 watt amp, dual channel, 16 max), the ECS-50 (50 watt amp, 16 max) or ECS-125 (125 watt amp, 16 max)
|
|
 |
IFP-1000ECS
• Analog addressable fire alarm control combined with integrated emergency communication system.
• Can Select ECS message as priority over fire alarm
• 15 recordable messages that can be mapped to eight ECS buttons
• Supports up to 7 ECS-RCU’s. The ECS-RCU meets the requirements for a LOC
• Programmable trigger inputs from an external source , such as a Monaco system, to either the VCM, RVM, or 5880. Up to 8 inputs available on each 5880 module
• Fire alarm and ECS combined in one easy to program system
|
 |
IFP-100ECS
• Analog addressable fire alarm control combined with integrated emergency communication system.
• Can Select ECS message as priority over fire alarm
• 15 recordable messages that can be mapped to eight ECS buttons
• Supports up to 7 ECS-RCU’s. The ECS-RCU meets the requirements for a LOC
• Programmable trigger inputs from an external source , such as a Monaco system, to either the VCM, RVM, or 5880. Up to 8 inputs available on each 5880 module
• Fire alarm and ECS combined in one easy to program system |
|
 |
ECS-550
• Standalone emergency communication system that may be used for fire applications, mass notification applications or both.
•50 watts of 25V audio power, expandable to 100 watts
• 2 amp Notification Appliance Circuit (NAC) output
•Up to 14 recorded messages
•8 Command Input Circuits to active message 1 to 8
•Integral supervised microphone
|
|
|
|
 |
IFP-FFT
• Addressable Fire Fighter Telephone System
• 24 zone system expandable to 72 zones
• Easy one button programming
• Compatible with all Silent Knight fire alarm control panels
• Up to 10 fire fighter remote hands sets can be on the system at one time
• Separate SLC circuit from the fire alarm control panel so you don’t use any points from your fire system. |
|
|
|
|
|
|
 |
IPGSM-4G
|
|
|
|
|
IPGSM-DP - Discontinued
IP Communicator
5104B
5128/5129
|
|
|
|
|
|
|
 |
Fire Alarm Aspiration Sensing Technology |
|
|
|
|
|
|
 |
Protecting and performing for the commercial building industry, Honeywell Analytics gas & flame detection products safeguard building occupants and assets.
E3 Point
Sensepoint XCD
FS20X
FS24X
SS2-A
SS2-AM SS3
SS4
|
|
|
|
|
|
|
|
 |
IFP-NET-3 |
|
|
|
|
|
|
|
 |
IDP-FIRE-CO |
|
|
|
|
|
|
|
 |
The Alertus Solution |
|
|
|